The Conclusions and Recommendations could be combined or, in long reports, presented in separate sections.

Conclusions and recommendations

If there aren’t any recommendations to be made because of the project, just call this section Conclusions.

The Conclusions section sums up the important thing points of your discussion, the primary options that come with your design, or even the significant outcomes of one’s investigation. As its function is always to round off the story of assembling your shed, it will:

  • be written to relate directly to the aims for the project as mentioned within the Introduction
  • indicate the extent to which the aims have now been achieved
  • summarise the findings that are key outcomes or information in your report
  • acknowledge limitations and work out recommendations for future work (where applicable)
  • Highlight the usefulness or significance of one’s work.

The conclusions should relate solely to the aims of the work:

The goal of this project is always to design a mobile phone tower for a suburban location..

The mobile phone tower presented here may be erected safely in a suburban street.

It requires a total area of no more than 2m 2 l, and has the safety that is following.

This investigation will review the quantity of passengers with the Monash University Clayton-Caulfield inter-campus bus in order to recommend adjustments to your ongoing service if needed.

Analysis associated with the survey data obtained in this project reveals that use of the Clayton-Caulfield inter-campus bus has grown by 24% in the past 5 years. It is strongly recommended that frequency be increased during peak usage.

The Conclusions section below is from a known level 2 Civil Engineering Alternative Designs report presenting two designs for a an overpass bridge. Click on the buttons that are coloured see the comments.

Conclusions

Each one of the two bridge designs Lecturer’s comment:
An elegant beginning for a Conclusions follows on neatly from the discussion that is preceding. In this full case, moreover it indicates that the aims of the project have been met. presented in this report fulfil the criteria specified when you look at the project brief. Both designs Lecturer’s comment:
The main findings https://essaywriters247.com or outcomes – in this full case one of the keys options that come with the designs – are then recapped. incorporate round piers on piled foundations, that are used because the soil conditions are unknown and perhaps unstable. Design 1, a simple i-girder that is composite, has got the benefit of being made of steel and therefore has longer spans and fewer piers.

Design 2, a beam that is super-T >Design 2 Lecturer’s comment:
The need for the end result – in cases like this the final recommendation – is actually stated. is therefore recommended. It gives Lecturer’s comment:
To finish off, the achievement associated with project is reinforced. An overpass that is affordable superior durability, and fully meets certain requirements regarding the design brief.

Always address limitations and suggest how they might be overcome in future work. The below that is excerpt from the Conclusions of a study on a project investigating the effect of pulsation on heat transfer in horizontal pipe flow.

Experimental results Lecturer’s comment:
Key conclusions drawn through the project. revealed that pulsed flow without flow reversal had no effect that is significant with steady flow. Preliminary experiments with reversed flow, however, clearly indicated increased heat transfer. This is likely due Lecturer’s comment:
Provide a explanation that is possible notable results, especially unexpected ones. to the large disturbances into the boundary that is hydrodynamic if the flow changes direction. Further research Lecturer’s comment:
Recommend further research to address any work that is extra think would be useful. is advised to determine the utmost achievable enhancement.

It should be noted that Lecturer’s comment:
Acknowledge limitations or errors and suggest explanations and/or solutions. the experimental results try not to buy into the theoretical equations. This can be because of the deposits which developed in the pipe, or even to thermocouple temperature that is inconsistent. Therefore, regular inspection of this test rig is recommended.

For an extremely long report, it really is acceptable to present the conclusions and recommendations in point form:

The prototype robot courier presented here has been shown to allow you to delivering documents autonomously in an working office environment. It offers demonstrated listed here aspects of mobile robotics:

  1. Localisation: The Kalman filter-based localisation algorithm achieved sub-centimeter accuracy under normal operating conditions.
  2. Environment modelling: The occupancy map was updated dynamically to incorporate obstacles not contained in the original map.
  3. Path planning: A distance path that is transform-based using obstacle transforms produced a globally optimal local entrapment-free road to the target.

Leave a Reply